日本機械学会論文集B編
Online ISSN : 1884-8346
ISSN-L : 1884-8346
ノート
大型熱音響冷却システムの実用化に向けた検討(管の断面積が熱から音へのエネルギー変換に与える影響)
北谷 裕次坂本 眞一黒田 健太朗渡辺 好章
著者情報
ジャーナル フリー

2011 年 77 巻 776 号 p. 1021-1025

詳細
抄録

Experimental investigation of the inner diameter in the thermoacoustic cooling system was carried out to confirm the effect for energy conversion efficiency. We carried out an experiment by using the thermoacoustic cooling system with 3 type inner diameters (24 mm, 42 mm, 100 mm). As results, acoustic power and a phase difference between sound pressure and particle velocity was varied. Moreover, it was confirmed that energy conversion efficiency in it changed with the variety of inner diameter. Energy conversion efficiency in it with inner diameter 100 mm was best of all. It is considered that a factor of improvement of energy conversion efficiency was change of phase difference between the sound pressure and the particle velocity.

著者関連情報
© 2011 一般社団法人 日本機械学会