Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Effect of flowability on the flow rate, polymerization shrinkage, and mass change of flowable composites
Ri-Mo KUChing-Chang KOChang-Mo JEONGMi-Gyoung PARKHyung-Il KIMYong Hoon KWON
Author information
JOURNAL FREE ACCESS

2015 Volume 34 Issue 2 Pages 168-174

Details
Abstract

As a lining or restoration material, flowable composites are popular due to their ease in use and agreeable marginal adaptation of tooth cavity. The purpose of the present study was to evaluate various properties of flowable composites which were claimed to be of high or low flowability by the manufacturers. For the study, twelve flowable composites from six different manufacturers were used. Based on the manufacturers’ claim, they were divided into two groups: high or low flowability. The products grouped in high flowability showed significantly higher (p<0.05) flow rate (flow distance), polymerization shrinkage, and microhardness (on the top surface), regardless of light-curing unit, than those grouped in low flowability. On the other hand, water sorption and solubility showed nonsignificantly different values regardless of flowability. Through the study, flow rate had low correlation with microhardness (R<0.23), polymerization shrinkage (R<0.60), and water sorption and solubility (R<0.36) regardless of light-curing unit.

Content from these authors
© 2015 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top