Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Evaluation of glass transition temperature and dynamic mechanical properties of autopolymerized hard direct denture reline resins
Kazuma TAKASEIkuya WATANABETadafumi KUROGIHiroshi MURATA
Author information
JOURNAL FREE ACCESS

2015 Volume 34 Issue 2 Pages 211-218

Details
Abstract

This study assessed methods for evaluation of glass transition temperature (Tg) of autopolymerized hard direct denture reline resins using dynamic mechanical analysis and differential scanning calorimetry in addition to the dynamic mechanical properties. The Tg values of 3 different reline resins were determined using a dynamic viscoelastometer and differential scanning calorimeter, and rheological parameters were also determined. Although all materials exhibited higher storage modulus and loss modulus values, and a lower loss tangent at 37˚C with a higher frequency, the frequency dependence was not large. Tg values obtained by dynamic mechanical analysis were higher than those by differential scanning calorimetry and higher frequency led to higher Tg, while more stable Tg values were also obtained by that method. These results suggest that dynamic mechanical analysis is more advantageous for characterization of autopolymerized hard direct denture reline resins than differential scanning calorimetry.

Content from these authors
© 2015 The Japanese Society for Dental Materials and Devices
Previous article Next article