Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Major Papers
Comparison of Brain Tumor Contrast-enhancement on T1-CUBE and 3D-SPGR Images
Mungunkhuyag MAJIGSURENTakashi ABETeruyoshi KAGEJIKenji MATSUZAKIMayumi TAKEUCHISeiji IWAMOTOYoichi OTOMINaoto UYAMAShinji NAGAHIROMasafumi HARADA
Author information
JOURNAL OPEN ACCESS

2016 Volume 15 Issue 1 Pages 34-40

Details
Abstract

Purpose: T1-Cube (GE HealthCare) is a relatively new 3-dimensional (3D) fast spin-echo (FSE)-based magnetic resonance (MR) imaging sequence that uses a variable flip angle to acquire gap-free volume scans. We compared the gadolinium enhancement characteristics of a heterogeneous population of brain tumors imaged by T1-Cube and then 3D fast spoiled gradient recall acquisition in steady state (3D FSPGR) 3-tesla MR imaging to identify the superior modality for specific diagnostic purposes.
Methods: We examined 61 lesions from 32 patients using the 2 sequences after administration of gadopentetic acid (Gd-DTPA; 0.1 mmol/kg). Two neuroradiologists independently measured each lesion twice using a region-of-interest (ROI) method. We measured the contrast-to-noise ratio (CNR), the difference in signal intensity (SI) between the tumor and normal white matter relative to the standard deviation (SD) of the SI within the lesion, for both post-contrast 3D FSPGR and post-contrast T1-Cube images of the same tumor and compared modality-specific CNRs for all tumors and in subgroups defined by tumor size, enhancement ratio, and histopathology.
Results: The mean CNR was significantly higher on T1-Cube images than 3D FSPGR images for the total tumor population (1.85 ± 0.97 versus 1.12 ± 1.05, P < 0.01) and the histologic types, i.e., metastasis (P < 0.01) and lymphoma (P < 0.05). The difference in CNR was even larger for smaller tumors in the metastatic group (4.95 to 23.5 mm2) (P < 0.01). In contrast, mean CNRs did not differ between modalities for high grade glioma and meningioma.
Conclusions: Gadolinium enhancement of brain tumors was generally higher when imaged by T1-Cube than 3D FSPGR, and T1-Cube with Gd enhancement may be superior to 3D FSPGR for detecting smaller metastatic tumors.

Content from these authors
© 2016 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top