日本建築学会環境系論文集
Online ISSN : 1881-817X
Print ISSN : 1348-0685
ISSN-L : 1348-0685
複合環境評価実験における非特異的尺度の「寒暑の印象」と「涼暖の印象」の比較
松原 斎樹島田 理良藏澄 美仁合掌 顕飛田 国人
著者情報
ジャーナル フリー

2011 年 76 巻 668 号 p. 877-885

詳細
抄録

Several analysis were applied to the experimental data obtained from the different environmental conditions and procedures to investigate the difference between two unspecific scales; the impression of “hot-cold” and “warm-cool”.
The main results are as follows; 1) “warm-cool” was different from “hot-cold” in the degree of the influence of temperature and the auditory factor, 2) the possibility was shown that “warm-cool” and “hot-cold” were not on the one-dimensional placement, 3) the difference of the degree of the influence of the auditory factor was conspicuously shown by combining with temperature.

著者関連情報
© 2011 日本建築学会
前の記事 次の記事
feedback
Top