SD295~785N/mm2級横補強筋を用いたRC梁の残留せん断ひび割れ幅制限値に基づく短期許容せん断力
市岡 有香子田川 浩之足立 将人益尾 潔
著者情報
ジャーナル フリー

2011 年 76 巻 662 号 p. 821-828

詳細
抄録
Allowable shear strength for repair-control was specified in AIJ Standard for Structural Calculation of Reinforced Concrete Structures revised in 2010. However, this allowable strength was defined by limited data and past research indicated that in some specimens no shear crack was initiated at allowable strength.
The authors conduct anti-symmetric bending tests of R/C beams using SD295 to 785 N/mm2 transverse reinforcement. It is confirmed that specimens with small transverse reinforcement ratio have frequently no shear crack at allowable strength. Finally, modified allowable shear strength accounting for transverse reinforcement ratio is proposed and verified to satisfy residual shear crack width limitation.
著者関連情報
© 2011 日本建築学会