2022 Volume 87 Issue 802 Pages 1247-1256
This paper investigated the dynamic response characteristic with focus on damped slit configuration of damped braced tube systems with oil dampers. According to the results, 1) damped braced tube system has over 10% 1st to 3rd damping ratio, 2) while the displacement and acceleration responses are simultaneously reduced up to maximized 1st mode damping ratio, the acceleration reduction effect may be getting worse after the peak, 3) while uniform damper distribution contributes to better damping performance, centralized damper distribution contributes to better period reduction.