AIJ Journal of Technology and Design
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
Materials and Construction
EXPERIMENTAL STUDY ON BASIC PERFORMANCE OF DEVICES WITH ELECTROMAGNETIC INDUCTION METHOD FOR THE MEASUREMENT OF COVER DEPTH OF REBAR
Hiroshi JINNAIKaoru TSUJIYAYutaka YOSHIDAMitsuo NAKAMURAKei KATOKouichi SATOMasato IIJIMASatoru NAMIKI
Author information
JOURNAL FREE ACCESS

2010 Volume 16 Issue 34 Pages 855-860

Details
Abstract
The performance of latest devices with electromagnetic induction method for the measurement of cover depth of rebar was confirmed by some experiments. The result is as follows. 1) The accuracy of latest devices was almost in the range of the standard value of JASS5T-608. 2) Mixture proportion of concrete and the age of specimen did not influence measurement values of latest devices with electromagnetic induction method.