日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
構造
泥炭層を挟む軟弱地盤におけるパイルド・ラフト基礎の原位置鉛直載荷試験
土屋 勉青木 涼永井 宏
著者情報
ジャーナル フリー

2011 年 17 巻 36 号 p. 483-486

詳細
抄録

Vertical loading tests are performed at highly organic soft ground to evaluate the piled raft foundations, in which the raft is not directly connected to pile heads. The rafts are made of reinforced concrete with 3.64m square and 0.15m thickness with 21kN/m2 loadings, and four H-shaped 5m long PC piles arranged at the corner of raft. The settlement and the axial stress of piled raft foundations are compared to those of a mat foundation and a single pile tested at the same site.

著者関連情報
© 2011 日本建築学会
前の記事 次の記事
feedback
Top