Improvement of Chromium(VI) Extraction from Acidic Solutions Using a Poly(vinyl chloride)-based Polymer Inclusion Membrane with Aliquat 336 as the Carrier
Shigehiro KAGAYATomonori MAENOKazuma ITOMakoto GEMMEI-IDERobert W. CATTRALLSpas D. KOLEV
Author information
JOURNAL FREE ACCESS

2017 Volume 33 Issue 5 Pages 643-646

Details
Abstract

An important reason for the inefficient extraction of Cr(VI) from its acidic solutions into polymer inclusion membranes (PIMs), consisting of poly(vinyl chloride) as the base-polymer and Aliquat 336 as the carrier, was found to be associated with the leaching of Aliquat 336 from the PIMs into the solutions, where it subsequently reduced the anionic Cr(VI) species to cationic Cr(III) species. The PIM extraction efficiency for Cr(VI) was significantly improved by the addition of NaNO3 to the solutions, which suppressed the leaching of Aliquat 336 and the reduction of Cr(VI) to Cr(III).