Analysis of 134Cs, 137Cs and 40K in the Certified Reference Material of Brown Rice by Gamma-ray Spectrometry Using a Ge Detector — Part 2: Uncertainty Evaluation —
Chushiro YONEZAWAKatsuhiro SHIRONOTomoko HARAGA
Author information
JOURNAL FREE ACCESS

2017 Volume 66 Issue 1 Pages 27-37

Details
Abstract

The uncertainties of the analysis results of 134Cs, 137Cs and 40K in the Brown Rice certified reference material by gamma-ray spectrometry using a Ge detector have been evaluated. The massic activities of 134Cs, 137Cs and 40K in the CRM were determined by a simple comparison and efficiency curve methods using standard gamma-ray sources of the analyzing radionuclides and a multi-nuclides mixed standard source, respectively, for gamma-ray peak efficiency calibration. Standard uncertainties of constituted parameters of the model equations of the analysis methods were determined from close examination of each uncertainty component of the parameters. Although it is not contained in the model equations, a parameter of repeatability due to a variation of the sample volume, of the geometrical condition and of the sample preparation were evaluated by an experiment using radionuclide standard solutions of 137Cs and 152Eu. The evaluated combined standard uncertainties of each parameter of the model equations were further combined following the uncertainty propagation law and obtained expanded uncertainties multiplying by a coverage factor (k = 2). Gamma-ray peak efficiency and net peak count were the largest uncertainty components in the simple comparison method, and those of the other components were negligibly small. As compared to the simple comparison method, due to the additional component of true coincidence summing (TCS) correction and gamma-ray emission probability, expanded uncertainty of the efficiency curve method was larger than that of the simple comparison method. Due to lack of appropriate information on uncertainties for TCS correction of cascade gamma-rays from 134Cs, 5 % relative standard uncertainty, which was obtained from radioactivity analysis of the 134Cs standard source by the efficiency curve method, was assigned for the efficiency curve method of 134Cs. The utilization of a low background gamma-ray spectrometer and the development of an accurate correction method of TCS are required to obtain a smaller uncertainty of the analysis methods.

Content from these authors
© The Japan Society for Analytical Chemistry 2017
Previous article Next article
feedback
Top