Circulation Reports
Online ISSN : 2434-0790
Valvular Heart Disease
Identification of Anemia for Predicting Mid-Term Prognosis After Transcatheter Aortic Valve Implantation in Japanese Patients ― Insights From the OCEAN-TAVI Registry ―
Hiroshi OnodaHiroshi UenoTeruhiko ImamuraYohei UenoHiroyuki KuwaharaMitsuo SobajimaKoichiro KinugawaNorio TadaToru NaganumaMasahiro YamawakiFutoshi YamanakaShinichi ShiraiKazuki MizutaniMinoru TabataKensuke TakagiYusuke WatanabeMasanori YamamotoKentaro Hayashidathe OCEAN-TAVI Investigators
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML

2021 Volume 3 Issue 5 Pages 286-293

Details
Abstract

Background:Patients with anemia have a poor prognosis following transcatheter aortic valve implantation (TAVI). Given the unique distribution of hemoglobin levels in the Japanese cohort, the optimal cut-off hemoglobin value may help stratify Japanese patients’ mortality following TAVI.

Methods and Results:Data of patients who underwent TAVI were collected from the prospective multicenter Optimized transCathEter vAlvular iNtervention (OCEAN)-TAVI Registry. Receiver operating characteristic analysis was used to calculate a hemoglobin cut-off value to stratify 2-year mortality following TAVI. In all, 2,588 patients (mean [±SD] age 84.4±5.2 years, 795 men) were included in the study. Of these patients, 909 (35.1%) had anemia, which was defined as hemoglobin <10.9 g/dL for men and <10.4 g/dL for women. The presence of anemia, uniquely defined for the Japanese cohort, was independently associated with 2-year mortality following TAVI, with an odds ratio of 1.77 (95% confidence interval 1.39–2.25) adjusted for 14 other clinical variables.

Conclusions:The existence of anemia, uniquely defined for the Japanese cohort, was associated with mid-term mortality following TAVI.

Content from these authors
© 2021, THE JAPANESE CIRCULATION SOCIETY

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback