コンクリート工学論文集
Online ISSN : 2186-2745
Print ISSN : 1340-4733
ISSN-L : 1340-4733
赤外線サーモグラフィー法の検証結果と新たな点検手法の一考察
福岡 賢明石 行雄橋本 和明
著者情報
ジャーナル フリー

2004 年 15 巻 2 号 p. 59-68

詳細
抄録

It has been pointed out until now that diagnosis of the concrete structure by the infrared thermography method has a high possibility of incorrect-detecting reflection and thermal radiation, and that judgment of the time suitable for investigation cannot be checked spot. Furthermore, even if it judges it as the unusual part by the infrared thermography method, the damage situation of the unusual part cannot be guessed. To solve such a problem, by this research, a damage situation can be guessed to some extent by performing heat conduction analysis and the scope of an infrared camera was checked by conducting an indoor experiment. In the main issue, the new check technique is proposed based on these research results. While this technique can judge objective time suitable for investigation, it becomes possible to guess a damage situation in a certain amount of accuracy.

著者関連情報
© 公益社団法人 日本コンクリート工学会
前の記事 次の記事
feedback