電気製鋼
Online ISSN : 1883-4558
Print ISSN : 0011-8389
ISSN-L : 0011-8389
アーク炉排ガスによるスクラップ予熱について
岸田 壽夫浅野 重雄鵜飼 敦杉浦 三朗
著者情報
ジャーナル フリー

1983 年 54 巻 1 号 p. 31-42

詳細
抄録

Based on the test results with a miniature preheater of 0.25ton capacity and measurements of temperature and volume of exhaust gas from a 25 ton electric arc furnace, a commercial scale scrap preheater was designed and installed to utilize exhaust gas from a 25 ton arc furnace. In the commercial operation of the installed preheater the following operation results were achieved after several improvements;
Item Reduction
Tap to tap time 8 min/heat
Power consumption 50kWh/ch·t
Electrode consumption 0.7kg/ch·t
Refractory consumption 17%
Production cost 670yen/ch·t