Effects of taper and space settings of telescopic Ce-TZP/A crowns on retentive force and settling
Shusuke NAKAGAWAKatsunori TORIIMasahiro TANAKA
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 2016-258

Details
Abstract

The aim of this study was to investigate the effect of the taper and space setting of using Ce-TZP/A on retentive force and secondary crown settling. The taper were 2°, 4°, and 6°, and the space settings were 0 and 10 μm. The applied loads were 50 and 100 N. The taper had a significant effect on retentive force and settling at both loads (p<0.05). The space settings did not have a significant effect on retentive force or settling at either load (p<0.05). The taper of the telescopic crowns and the load affected the retentive force and the settling.