Comparison between direct chairside and digitally fabricated temporary crowns
Adil O. ABDULLAHSarah POLLINGTONYi LIU
著者情報
ジャーナル フリー 早期公開

論文ID: 2017-315

この記事には本公開記事があります。
詳細
抄録

The mechanical properties of temporary crowns are considered to be crucial in order to achieve successful definite restorations. This study compared marginal fit, internal fit, fracture strength and mode of fracture of CAD/CAM temporary crowns to direct chairside counterparts. An upper left first premolar Frasaco tooth was prepared for all-ceramic crown. The materials used for comparison were VITA CAD-Temp®, ArtBloc®Temp, PMMA DISK and Acrytemp (control group). The crowns were divided into four groups (n=10). Each crown was investigated for the above parameters. Statistical analysis was performed using SPSS v.20. The average marginal gap, internal gap and fracture strength showed statistically significant difference between groups (p<0.01). The fracture mode showed statistically non-significant difference (p>0.05) among experimental groups. The CAD/CAM temporary crowns demonstrated superior mechanical properties compared to direct handmade counterparts.

著者関連情報
© 2018 The Japanese Society for Dental Materials and Devices