主催: 一般社団法人日本液晶学会
会議名: 2019年 日本液晶学会討論会
開催地: 筑波大学
開催日: 2019/09/04 - 2019/09/06
We discuss the flicker shift phenomenon generated by several factors in FFS-mode LCD. We propose the method to compare measurement result with simulation result of flicker minimum and transmittance minimum DC offset voltage at each gray level. Although flicker minimum and DC minimum DC offset voltage vary depending on gray level, measurement result and simulation result show similar tendency. Through this method we separate separate flicker shift factors.