液晶討論会講演予稿集
Online ISSN : 2432-9959
Print ISSN : 1880-3539
ISSN-L : 1880-3539
第22回 液晶討論会
セッションID: 3C06
会議情報

汚染の電圧保持率への影響
*笹木 宣良塩谷 計二
著者情報
会議録・要旨集 フリー

詳細
抄録
We studied quantitatively the influence of ionic and organic contaminants on the voltage holding ratio(VHR) of liquid crystal display panels, which is related to the display image stability of TFT-LCD, by means of forced contamination experiments and calculated simulation. From the simulation, we found that both a 0.3n C/cm2 ion density generated from NaCl and a contamination of about 0.2% due to N-methyl-2-pyrolidone cause decrease in the VHR from 100 to 95%. Inorganic contaminants cause the VHR to decrease more drastically than organic contaminants.
著者関連情報
© 1996 一般社団法人日本液晶学会
前の記事 次の記事
feedback
Top