Electrochemistry
Online ISSN : 2186-2451
Print ISSN : 1344-3542
ISSN-L : 1344-3542
Communications
Response Properties of Amperometric CO Sensor Using a Polybenzimidazole (PBI) Membrane above 140°C
Kei MOCHIZUKIHirotaka IWATSUMasao SUDOHYoshiaki ISHIGUROTakayuki SUZUKI
Author information
JOURNAL FREE ACCESS

2010 Volume 78 Issue 2 Pages 129-131

Details
Abstract

A new amperometric sensor based on proton conducting membranes to CO was investigated. It was observed that the sensor current density showed almost linearity against CO concentration in the range of 0–3000 ppm at 200°C. In addition, the sensitivity at less than 300 ppm CO was detected clearly using phosphoric acid doped polybenzimidazole (PBI) membrane. It was found that PBI membrane had high selectivity of CO to H2 in combustor exhaust gases at 200°C. Sensor performance using PBI membrane was less influenced by humidity than Nafion.

Content from these authors
© 2010 The Electrochemical Society of Japan