Global Health & Medicine
Online ISSN : 2434-9194
Print ISSN : 2434-9186

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Consistency of the results of rapid serological tests for SARS-CoV-2 among healthcare workers in a large national hospital in Tokyo, Japan
Shohei YamamotoAkihito TanakaShinji KobayashiYusuke OshiroMitsuru OzekiKenji MaedaKouki MatsudaKengo MiyoTetsuya MizoueWataru SugiuraHiroaki MitsuyaHaruhito SugiyamaNorio Ohmagari
著者情報
ジャーナル フリー 早期公開

論文ID: 2021.01022

この記事には本公開記事があります。
詳細
抄録

We assessed the consistency of seropositive results of three rapid immunoassays (Kits A, B, and C) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) compared to highly accurate serological tests (Abbott and Roche) among healthcare workers in a hospital in Tokyo. The seroprevalence of SARS-CoV-2 immunoglobulin G was 0.41%, 2.36%, and 0.08% using Kits A, B, and C, respectively. Of the 51 samples that were seropositive on any rapid test, all were seronegative on both the Abbott and the Roche assays. Given that the seroprevalence of SARS-CoV-2 immunoglobulin G varied widely according to the choice of rapid test and the rapid test results were inconsistent with the results of highly accurate tests, the diagnostic accuracy of rapid serological tests for SARS-CoV-2 should be assessed before introducing these tests for point-of-care testing or surveillance.

著者関連情報
© 2021 National Center for Global Health and Medicine