Ionizing Radiation
Online ISSN : 2758-9064
Development of MSGC with GLG method
H. NikoK. FujitaH. TakahashiP. SiritiprussameeM. NakazawaM. FurusakaS. KishimotoT. InoJ. SuzukiT. OkuH. Toyokawa
Author information
JOURNAL FREE ACCESS

2006 Volume 32 Issue 2 Pages 140-144

Details
Abstract

  Recently, we have proposed a new Global-Local Grouping method, which divides a signal charge into two parts: one provides a coarse position and the other provides a fine position. In this paper, we introduce a new Global-Local Grouping readout method, which utilizes a geometrical charge division method for cathode signals. We have fabricated an ultra-long microstrip detector whose sensitive length is 640 mm. Test measurement with neutron beam showed good global and local position resolutions, that were estimated to be 32mm and 1.2mm, respectively.

Content from these authors
© 2006 The author(s)
Previous article Next article
feedback
Top