圧力技術
Online ISSN : 1347-9598
Print ISSN : 0387-0154
ISSN-L : 0387-0154
論文
石油精製圧力容器の補修溶接性に関する研究
-第1報 経時劣化材補修溶接部の再現と再供用後の健全性評価-
茅野 林造長谷川 龍雄井上 洋一
著者情報
ジャーナル フリー

2002 年 40 巻 2 号 p. 89-95

詳細
抄録

In order to simulate tempered and hydrogen embrittled pressure vessel steel in the laboratory, hydrogen exposure in autoclave equipment and repair welding using shielded-metal arc weld consumable for the large size specimen exceeded 100mm thickness were carried out. Minimum stainless steel overlay thickness that became a standard of the repair time estimation was obtained by investigation of characteristics at the repair welds, such as dilution, hardness and microstructure. In addition, tensile test were carried out using re-hydrogen exposed specimen, and serviceability of recent generation 2. 25Cr-1Mo pressure vessel steel repair welds was confirmed.

著者関連情報
© 2002 一般社団法人 日本高圧力技術協会