圧力技術
Online ISSN : 1347-9598
Print ISSN : 0387-0154
ISSN-L : 0387-0154
解説
高温高圧配管フランジへの保温施工による漏洩メカニズム
金丸 伸一郎宇野 義明
著者情報
ジャーナル フリー

2023 年 61 巻 4 号 p. 173-177

詳細
抄録
Flange connection is widely utilized to connect piping, fittings and valves in chemical, refinery and petrochemical industry. However, leakage incidents from gasket surface have been happening at bolted flange connections. The authors experienced an incident that the existence of insulation, which is used to reduce heat loss of process fluids in piping, affected leakage at high temperature-high pressure (HT-HP) piping flange connection. In this paper, leakage mechanism with insulation at HT-HP piping flange connection is explained from the point of view of bolt tension calculated using finite element analysis and relaxation. Consequently, it is recommended that insulation not be used for HT-HP piping flange connection, and a weather seal or a personal protection be used instead.
著者関連情報
© 2023 一般社団法人 日本高圧力技術協会
前の記事 次の記事