電気学会論文誌C(電子・情報・システム部門誌)
Online ISSN : 1348-8155
Print ISSN : 0385-4221
ISSN-L : 0385-4221
塗装後自動車ボデー寸法計測のための2方向同時撮像方式視覚センサ
加納 善明小関 修吉岡 貴芳渡辺 與作
著者情報
ジャーナル フリー

1998 年 118 巻 4 号 p. 536-543

詳細
抄録

In dimension inspection of painted automotive body, the conventional method using slit light cannot detect the shape of edges of adjacent body parts. Thus the conventional method is not able to measure accurately the gap of between body parts. A new vision sensor based on simultaneous imaging from two directions has been developed. The sensor has a imaging unit. The imaging unit is consisted of a slit light source, a TV-camera, two triangular mirrors and four plane mirrors. The two edge of facing body parts are observed respectively from upper left and upper right directions by the imaging unit. Thus the TV-camera of the imaging unit is able to take simultaneously two edge images. At this time, in the TV-camera image, the overlapping of the two edge images occurs. We analyzed the characteristic of the overlapping of the images and showed the design index to get the clear edge images.
The sensor used the imaging unit measures the gap and flushness with accuracy of within ±0.1mm without the influence of the shape of body edge.

著者関連情報
© 電気学会
前の記事 次の記事
feedback