2006 Volume 126 Issue 11 Pages 1486-1492
This paper describes a direct-power-controlled current-source PWM rectifier, and presents its experimentally examined operation characteristics. The most important feature of this strategy is a direct selection of switching states of the PWM rectifier on the bases of instantaneous control errors of active and reactive power. In addition, this paper describes a theoretical analysis on relationship between the instantaneous power and the switching states, which is essential to compose a switching-state table in the controller. Feasibility of the proposed strategy is verified through experimental tests, using a 2-kW prototype setup. As a result, the maximum total input power factor of 99.86% and the maximum total efficiency of 92.72% have been confirmed in the tests as well as high-speed responses of the power.
The transactions of the Institute of Electrical Engineers of Japan.C
The transactions of the Institute of Electrical Engineers of Japan.B
The transactions of the Institute of Electrical Engineers of Japan.A
The Journal of the Institute of Electrical Engineers of Japan