大容量非接触給電トランスの無効電力を考慮した設計法
山本 浩平丸山 貴嗣近藤 圭一郎柏木 隆行
著者情報
ジャーナル フリー

2013 年 133 巻 3 号 p. 378-385

詳細
抄録

Problems in high-power contactless power transmission systems using series and parallel resonance capacitors arise from the maximum voltage limit of the series capacitor owing to high reactive power. In this study, the characteristics of reactive power are analyzed using an equivalent circuit and the contactless power transfer system is designed considering reactive power characteristics. The self-inductance and the frequency can determine the distribution of reactive power at the primary side and the secondary side. In addition, the optimal winding number and size of the coil and the appropriate frequency are investigated by electromagnetic field analysis.