1996 Volume 116 Issue 10 Pages 1018-1026
This paper deals with leakage current and it's high-frequency zero-phase-sequence equivalent circuit in an induction motor driven by a PWM inverter. The leakage current flows through stray capacitances between stator windings and iron core (frame) of an induction motor at the switching instants of the inverter transistors. The high-frequency zero-phase-sequence equivalent circuit is derived based on the frequency characteristics of the high-frequency zero-phase-impedance of the induction motor. The validity of the derived equivalent circuit is confirmed by simulation and experimental results.
The transactions of the Institute of Electrical Engineers of Japan.C
The transactions of the Institute of Electrical Engineers of Japan.B
The transactions of the Institute of Electrical Engineers of Japan.A
The Journal of the Institute of Electrical Engineers of Japan