IEEJ Journal of Industry Applications
Online ISSN : 2187-1108
Print ISSN : 2187-1094
ISSN-L : 2187-1094
Selected and English Translation Paper of IEEJ Trans. IA
Control Method of Failure for One Unit of Double Three-Phase-Wound Permanent Magnet Synchronous Machine Drive System Using Coupling of Dual Resolver
Tatsuya MoriHiroko IkedaToshihiro MatsunagaKenji IkedaKenta Kubo
著者情報
ジャーナル フリー

2024 年 13 巻 5 号 p. 587-593

詳細
抄録

This paper presents a control method for the failure of one of the two units of a double three-phase-wound permanent magnet synchronous machine drive system without contact between these two units by estimating the state of the other unit based on magnetic coupling of a dual resolver. This paper proposes an another unit state estimation algorithm, in which the second unit extracts coupling signals from the output windings of the dual resolver. If the level of the extracted signals is smaller than threshold value, the first unit is determined to have failed. Experiments were conducted and the results showed the effectiveness of the proposed method.

著者関連情報
© 2024 The Institute of Electrical Engineers of Japan
前の記事 次の記事
feedback
Top