IEEJ Transactions on Power and Energy
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
Special Issue Paper
Performance Evaluation of National Standard Class Measurement System for Lightning Impulse Voltage
Takayuki WakimotoHiroyuki ShimizuMasaru Ishii
Author information
JOURNAL FREE ACCESS

2007 Volume 127 Issue 1 Pages 314-320

Details
Abstract
An impulse voltage measuring system of which performance is able to regard as the national standard class in Japan was developed in 1999. The same year, international comparison tests of the impulse measuring system were carried out among 23 countries. The performance of the impulse voltage measuring system in Japan was excellent.
For this measuring system in Japan, some tests to evaluate various performances of the components were carried out and the overall uncertainty of the system was estimated after the international comparison tests.
In this paper, the national standard class impulse voltage measuring system in Japan is described and its measuring uncertainty is discussed.
Content from these authors
© 2007 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback
Top