Japanese Heart Journal
Online ISSN : 1348-673X
Print ISSN : 0021-4868
ISSN-L : 0021-4868
Assay of Heparin in Plasma Using a Chromogenic Substrate and Its Clinical Applications
Hiroshi HASEGAWAYutaka OGUMAHideaki TAKEITsukasa SEYAMasao YAMAUCHIToshio MURAKOSHIHiroshi NAGATAMakoto MURAO
Author information
JOURNAL FREE ACCESS

1980 Volume 21 Issue 3 Pages 367-380

Details
Abstract
The concentration of heparin in plasma was measured using a chromogenic substrate. It appeared that the measurement of heparin concentration in plasma was important in therapeutic control and evaluation of heparin. There was a correlation between the activated partial thromboplastin time (APTT) and heparin concentration in plasma, but since the gradients of regression line differed in each of the cases, measurement of APTT alone would give a different estimate of heparin concentration in each case. Fibrinopeptide A (FPA) is considered as the best indicator for evaluation of therapeutic effects of heparin. Therapeutic heparin concentrations were defined as ranging from 0.2 to 1.2IU/ml because the normalization of FPA was observed and there happened no hemorrhagic accidents in that range.
Content from these authors
© by International Heart Journal Association
Previous article Next article
feedback
Top