International Journal of Affective Engineering
Online ISSN : 2187-5413
ISSN-L : 2187-5413
Eye Motion Detection using Electrooculography for Bio-signal Interfaces
Daisuke TAMAKIHisaya TANAKA
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: IJAE-D-24-00029

Details
Abstract

This study aimed to determine the EOG interface that can be used for ALS, which can be used without preparation. Thus, eye movement detection was proposed using the RMS of the active threshold (AT) and K-NN methods. The AT method is dynamically performed using the RMS. In this study the combined use of both methods was described. Experiments on waveform detection accuracy were conducted on 19 healthy subjects between the ages of 20 and 29 years. The hit rate of the proposed method was 94%, and the false alarm rate was 9%. Next, we calculated the information transfer rate (ITR), a popular evaluation index for BCI. Using the proposed method, the ITR was bits/min. A P300 Speller is one of the bio-signal interfaces, that its ITR is 11 bits/min. Therefore, the ITR of the proposed method was higher than that of other bio-signal interfaces. Furthermore, the proposed method has shown great application potential as an interface.

Content from these authors
© 2025 Japan Society of Kansei Engineering

This article is licensed under a Creative Commons [Attribution 4.0 International] license.
https://creativecommons.org/licenses/by/4.0/
Previous article Next article
feedback
Top