International Journal of Automation Technology
Online ISSN : 1883-8022
Print ISSN : 1881-7629
ISSN-L : 1881-7629
Special Issue on Laser-Based/Assisted Manufacturing
Generation of Biocompatible Titanium Alloy Surfaces Including Calcium and Phosphorus Elements by Laser-Induced Mist Spraying Wet Treatment
Atsushi EzuraKazutoshi KatahiraJun Komotori
著者情報
ジャーナル オープンアクセス

2020 年 14 巻 4 号 p. 575-581

詳細
抄録

Titanium alloys are widely used for the hard tissue substitute implants. However, it is necessary to improve interfacial biocompatibility to reduce adhesion period. For improvement of biocompatibility of Ti-6Al-4V ELI alloys, texture and chemical composition on contact part with biological tissue play very important roles. In this research, micro texture was generated on the Ti-6Al-4V ELI alloy surfaces utilizing laser irradiation, in order to improve biocompatibility. The biocompatibility was evaluated by osteoblast cell culture assays. The results indicated the surface having micro texture improve biocompatibility as compared with untreated surface. This was considered in order the fact that the formed modified surface had hydrophilicity, thereby improving the cell compatibility, and the cell adhesion due to the complicated shape. In addition, mist of glycerophosphoric acid calcium aqueous solution was applied on the laser irradiated area. As result, micro texture including Ca and P elements was generated on the Ti-6Al-4V ELI alloy surfaces. When laser was irradiated, glycerophosphoric acid calcium aqueous solution was applied as mist flowed on the test pieces as droplet. The velocity of droplet fluid was relatively fast, so that laser irradiation was unhindered access to the surface of test pieces and the treatment was stable. In order to estimate biocompatibility, culture assays using osteoblast cells were conducted on the treated surface having micro texture including Ca and P elements. As results, it was clearly that biocompatibility of the specimen treated by laser with glycerophosphoric acid calcium aqueous solution mist more improved than either untreated specimen or treated specimen soaked in glycerophosphoric acid calcium aqueous solution.

著者関連情報

この記事は最新の被引用情報を取得できません。

© 2020 Fuji Technology Press Ltd.

This article is licensed under a Creative Commons [Attribution-NoDerivatives 4.0 International] license (https://creativecommons.org/licenses/by-nd/4.0/).
The journal is fully Open Access under Creative Commons licenses and all articles are free to access at IJAT Official Site.
https://www.fujipress.jp/ijat/au-about/
前の記事 次の記事
feedback
Top