International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
Special issue for 2010 International Conference on Pumps and Fans, October 18-21, 2010, Hangzhou, China
Tip Clearance Losses - A Physical Based Scaling Method
Peter F. PelzSascha Karstadt
Author information
JOURNAL FREE ACCESS

2010 Volume 3 Issue 4 Pages 279-284

Details
Abstract

Tip clearance losses occur in every turbomachine. To estimate the losses in efficiency it is important to understand the mechanism of this secondary flow. Tip clearance losses are mainly caused by a spiral vortex formed on the suction side of the blade of a turbomachine, which induces a drag and also has an influence on the incident flow of the blades. In this paper a physical based scaling method is developed out of an analytical ansatz for the tip clearance losses. This scaling method is validated by measurements on an axial fan with five different tip clearances.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2010 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
Next article
feedback
Top