Japanese women now account for 43 percent of the labor force. A number of them are involved in construction, agricultural and forestry jobs. The aim of this study was to establish a non-invasive technique for the evaluation of peripheral circulatory functions in women with Raynaud's phenomenon (RP) and introduce a specific method for the assessment of vascular disturbances in females exposed to hand-transmitted vibration. The subjects of this study were 10 women with primary RP, 7 women with progressive systemic sclerosis (PSS) secondary to RP, and 17 females who were included as the control group. The evaluation of peripheral circulatory functions in all subjects was based on the values of finger blood flow (FBF) and finger skin temperature (FST) measured before, during and following a 5-min recovery period after the hand was immersed in cold water (5°C, 1 min). The measured values of FBF and FST of the primary RP group before and after the immersion test were significantly (p<0.01) lower compared to those of the control group. The technique applied in this study could be used as a non-invasive and tolerable technique to determine the digital circulatory functions in female subjects with RP.