Industrial Health
Online ISSN : 1880-8026
Print ISSN : 0019-8366
ISSN-L : 0019-8366

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Towards a wearable sensor system for continuous occupational cold stress assessment
Hanne AUSTADØystein WIGGENHilde FÆREVIKTrine M. SEEBERG
著者情報
ジャーナル フリー 早期公開

論文ID: 2017-0162

この記事には本公開記事があります。
詳細
抄録

This study investigated the usefulness of continuous sensor data for improving occupational cold stress assessment. Eleven volunteer male subjects completed a 90-120-minute protocol in cold environments, consisting of rest, moderate and hard work. Biomedical data were measured using a smart jacket with integrated temperature, humidity and activity sensors, in addition to a custom-made sensor belt worn around the chest. Other relevant sensor data were measured using commercially available sensors. The study aimed to improve decision support for workers in cold climates, by taking advantage of the information provided by data from the rapidly growing market of wearable sensors. Important findings were that the subjective thermal sensation did not correspond to the measured absolute skin temperature and that large differences were observed in both metabolic energy production and skin temperatures under identical exposure conditions. Temperature, humidity, activity and heart rate were found to be relevant parameters for cold stress assessment, and the locations of the sensors in the prototype jacket were adequate. The study reveals the need for cold stress assessment and indicates that a generalised approached is not sufficient to assess the stress on an individual level.

著者関連情報
© 2018 by National Institute of Occupational Safety and Health
feedback
Top