ISIJ International
Online ISSN : 1347-5460
Print ISSN : 0915-1559
ISSN-L : 0915-1559
Effect of Applied Cathodic Potential on Susceptibility to Hydrogen Embrittlement in High Strength Low Alloy Steel
Shin-ichi KomazakiRie MaruyamaToshihei Misawa
Author information
JOURNAL FREE ACCESS

2003 Volume 43 Issue 4 Pages 475-481

Details
Abstract

In order to investigate the effects of applied cathodic potential and chemical hydrogen absorption promoter (thiourea) on the susceptibility to hydrogen embrittlement of the high strength low alloy (HSLA) steel, slow strain rate tensile (SSRT) tests were conducted in various buffer aqueous solutions of pH 10.0. During SSRT tests, the specimens were cathodically polarized under potentiostatic control. Polarization levels were varied from the corrosion potential (Ecorr) to hydrogen gas evolution potential (EH2 gas), including the adsorbed hydrogen potential (EHads) determined by cyclic voltammetry (CV). Additionally, thermal desorption spectroscopic (TDS) analyses were applied to the specimens fractured by SSRT test and the dependence of hydrogen absorption characteristic on applied potential was also examined for understanding the SSRT test results. Experimental results revealed that the hydrogen embrittlement behavior was strongly dependent on the applied cathodic potential. In the EHads region, the susceptibility to hydrogen embrittlement increased with increasing cathodic overpotential. On the other hand, in the EH2 gas region, the susceptibility was independent of the applied potential. Moreover, by adding thiourea to the solution, the susceptibility to hydrogen embrittlement increased slightly in the EH2 gas region compared with that in the solution without thiourea. There was a relatively good correlation between the amount of hydrogen absorption per unit time (CH/tf) and the time to failure (tf), namely, the susceptibility to hydrogen embrittlement has a tendency to increase monotonically with increasing CH/tf. As a consequence, the potential dependence of hydrogen embrittlement was closely associated with the variation in hydrogen absorption rate under applied potential.

Content from these authors
© The Iron and Steel Institute of Japan
Previous article Next article
feedback
Top