日本原子力学会誌
Online ISSN : 2186-5256
Print ISSN : 0004-7120
臨界警報装置
清瀬 量平関口 善之宮本 不二男丸山 正倫九十九 清彦西堀 俊雄北原 義久松本 徳太郎中田 啓斎藤 親八木 英二山田 泰正甲野 啓一南 賢太郎内藤 奎爾岩井 誠村野 徹辻野 毅星野 幸二辻本 忠黒沢 文夫富島 広大内 親章亀ケ谷 勝之助萩野 谷徹松野 清加藤 仁三大西 武磯川 育男森 竜二田中 忠三郎
著者情報
ジャーナル フリー

17 巻 (1975) 8 号 p. 404-413

詳細
PDFをダウンロード (643K) 発行機関連絡先
抄録

This report includes a summarized version of a design standard proposed by the Research Committee on Standards for Criticality Alarm Systems, which was organized in the Atomic Energy Society of Japan in October, 1973 and which terminated its activities in March, 1975. Some additional information on criticality alarm systems are included, such as the basic characteristics of criticality accidents, examples of criticality alarm systems installed in Japanese, as well as in some foreign nuclear fuel facilities, functional checks and tests of criticality alarm systems, and a survey of relevant standards already proposed and used in U.S.A., U.K. and other countries. The proposed standard incorporates reliability considerations and a criticality accident to be assumed in designing criticality alarm systems.