エアロゾル研究
Online ISSN : 1881-543X
Print ISSN : 0912-2834
ISSN-L : 0912-2834
研究論文
電気集塵装置の性能に及ぼす電気流体力学場の影響 (集塵効率に及ぼすEHD数の影響)
村井 一弘川島 陽介坂田 亮彦村上 哲郎
著者情報
ジャーナル フリー

1996 年 11 巻 2 号 p. 129-136

詳細
抄録

A numerical simulation is conducted to investigate the effect of the ionic wind and the effect of the electro-hydro-dynamic (EHD) flow field on the collection efficiency of a duct type electrostatic precipitator for the case of submicron size dust particles. The calculations for the ionic flow field and the EHD flow field are carried out by the Finite Element Method. Re- sults show that the flow pattern of gas in the EHD flow field depends on the EHD number. The collection efficiencies are at minimum values when the particle diameter is about 0.3 μm, both without and with the ionic wind. The collection efficiency is reduced considerably in the EHD flow field. An increase in the EHD number does not always mean that the collection efficiency will increase uniformly. The collection efficiency curves have maximum values at the EHD numbers which range within the limits in the case that the particle size is from 0.05 to 0.30 μm approximately.

著者関連情報
© 1996 日本エアロゾル学会
前の記事 次の記事
feedback
Top