JAPANESE CIRCULATION JOURNAL
Online ISSN : 1347-4839
Print ISSN : 0047-1828
ISSN-L : 0047-1828
Clinical Investigation
Pulse Infusion Thrombolysis (PIT) for Large Intracoronary Thrombus
Preventive Effect Against the `No Flow' Phenomenon in Revascularization Therapy for Acute Myocardial Infarction
Taro SaitoSeiji HokimotoFumiyuki IshibashiKatsuo NodaShuichi Oshima
Author information
JOURNAL FREE ACCESS

2001 Volume 65 Issue 2 Pages 94-98

Details
Abstract

Because large thrombus is a limitation for revascularization in acute myocardial infarction (AMI), the present study evaluated the effectiveness of pulse infusion thrombolysis (PIT) in patients with an AMI with a large (>15 mm) coronary thrombus, focusing on the occurrence of the `no flow' phenomenon. The retrospective study compared patients treated before (1988-95; Group A, n=74) and after (1996-99; Group B, n=40) the use of PIT, using the following parameters: lesion success (<50% stenosis during 30-min observation), procedural success (lesion success plus TIMI grade 3 flow), procedural no flow (TIMI grade 0 flow during the procedure with `back and forth movement' of contrast dye after lesion success), persistent no flow (consistent no flow without any flow improvement at the final visualization despite intensive treatment), reocclusion rate and in-hospital death. Group B was significantly better than Group A in procedural success (90% vs 66%; p=0.005), procedural `no flow' (51% vs 15%; p<0.001), and persistent `no flow' (34% vs 10%; p<0.05). Subgroup comparison was performed among the following groups: Direct-BA group (n=44): treated with mechanical angioplasty alone; ICT-BA group (n=40): treated with prior intracoronary thrombolysis and angioplasty; and PIT-BA group (n=30): treated with PIT and angioplasty. There were no differences in thrombus length and lesion success among these 3 groups. Procedural success was best achieved in PIT-BA: 97% vs 52% for Direct-BA (p=0.003) and 68% for ICT-BA (p=0.009). Procedural `no flow' was least in PIT-BA: 50% vs 3.3% for Direct-BA (p=0.003) and 25% vs 3.3% for ICT-BA (p=0.042). Persistent `no flow' was less frequent in PIT-BA than Direct-BA: 32% vs 3.3% (p=0.009). However, the difference between ICT-BA and Direct-BA was insignificant: 13% vs 3.3% (p=0.53). There were no differences in reocclusion rate and in-hospital death among the 3 subgroups. And there were no differences between Direct-BA and ICT-BA in any parameters. PIT was effective in preventing `no flow' in the mechanical revasculalization for AMI especially those cases with a large thrombus. (Jpn Circ J 2001; 65: 94 - 98)

Content from these authors
© 2001 THE JAPANESE CIRCULATION SOCIETY
Previous article Next article
feedback
Top