CORROSION ENGINEERING DIGEST
Online ISSN : 1884-1155
Print ISSN : 0010-9355
ISSN-L : 0010-9355
Application of Operational Amplifier in Corrosion Study
(Part II) Trial Construction of a Potentiostat Using an OP Amplifier
Hiroji NakauchiTakehito UminoYoshimune Naganuma
Author information
JOURNAL FREE ACCESS

1973 Volume 22 Issue 12 Pages 513-516

Details
Abstract

A trial construction of battery operated mini potentiostat for potentiostatic test in field was performed by using an OP amplifier. A circuit diagram was presented and the detail of construction was described. Potentiostatic behaviors of mild steel were examined in fresh and polluted sea water, and it was certified that this potentiostat operated satisfactorily in both laboratory and field test. A modification for raising the input impedance of the instrument was briefly described.

Content from these authors
© Japan Society of Corrosion Engineering
Previous article Next article
feedback