Zairyo-to-Kankyo
Online ISSN : 1881-9664
Print ISSN : 0917-0480
ISSN-L : 0917-0480
Design of CP System for Newly Constructed Pipelines with Respect to Cathodic Protection Criteria Based on DC and AC Current Densities Measured Using Probes
Yuji HosokawaFumio KajiyamaTomoyuki FukayaJun Kikuchi
Author information
JOURNAL FREE ACCESS

2002 Volume 51 Issue 6 Pages 269-274

Details
Abstract

Recently, the risks such as AC corrosion, overprotection and corrosion inside casing pipes are increasing on cathodically protected pipelines due to the changes in burial situations, application of new construction techniques and so on. Authors have proposed new cathodic protection (CP) criteria based on DC and AC current densities measured using probes that provide an appropriate assessment of those risks together with effective measures to eliminate those risks. The design of CP systems for newly constructed pipelines, on which those risks were likely to occur, was then successfully performed based on the new CP criteria. In this paper, actual procedures to design CP systems with respect to the new CP criteria are demonstrated. In addition, the methodology to eliminate the risk of AC corrosion is presented.

Content from these authors
© Japan Society of Corrosion Engineering
Previous article
feedback
Top