ケーブル・イン・コンジット導体ジョイントにおける超電導素線と銅スリーブ間の接触素線数と接触長分布に関する解析
中澤 忍手島 翔太郎荒井 大地宮城 大輔津田 理濱島 高太郎谷貝 剛布谷 嘉彦小泉 徳潔高畑 一也尾花 哲浩
著者情報
ジャーナル フリー

2011 年 46 巻 8 号 p. 474-480

詳細
抄録

It is observed that the measured critical currents of cable-in-conduit (CIC) conductors for ITER TF coils become lower than expected due to the unbalanced current distribution that is caused by contact resistance between the strands and the Copper (Cu) sleeves in CIC conductor joints. In order to evaluate the contact length, we identify the three-dimensional positions of all strands in the CIC conductor, and then measure the contact number and lengths of strands that appear on the surface of the cable to contact with the Cu sleeves. It is found that some strands do not appear on the surface of the cable, and the contact lengths are widely distributed with a large standard deviation. We develop a numerical code that simulates strand positions in the CIC, and then compare the analyzed contact strand number and contact length with measured ones. It is found that the results are in agreement, and hence the code can be used to evaluate the contact parameters. After varying the twist pitches of the sub-cables, we show that all strands appear on the cable surface and have contact lengths with small standard deviation. It is found that the twist pitches are a key parameter for optimization of the contact resistance.

著者関連情報
© 2011 公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)