低温工学
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
液体ヘリウムデュワーの熱解析及び蒸発速度の低減
倉岡 泰郎黒沢 淳白井 哲雄渡辺 哲史斎藤 勝郎三沢 健
著者情報
ジャーナル フリー

1977 年 12 巻 1 号 p. 19-27

詳細
抄録

Heat analysis of a wide aperture liquid helium dewar is described.
Radiant heat input from the top surface has been calculated accurately as far as possible. Absorption and reflection at the inner wall are treated by introducing a new concept of “effective solid angle”. Heat exchange between the cold evaporating gas and the dewar wall has been calculated as “apparent solid conduction” to the liquid surface. This factor is determined from the balance of the heat inputs to the liquid column and to the vapor column.
In order to estimate the radiant heat input from the top surface, evaporating rates of two dewars were analyzed. The inner wall of the first one was polished by #400 emery. The second dewar was painted with aquadag. Furthermore, in order to estimate “apparent solid conduction”, various heater powers have been supplied in the liquid helium.
The results suggest:
1) In the wide aperture liquid helium dewar, the radiant heat input from the top surface is the largest factor and can be calculated using “effective solid angle” which is function of dewar dimensions, liquid level and reflectivity of inner wall.
2) “Apparent solid conduction” is zero when the radiant heat input from the top surface is the largest one.
3) If the inner wall of the dewar is painted with aquadag, the radiant heat input from the top surface is reduced and “apparent solid conduction” becomes the largest factor.

著者関連情報
© 社団法人低温工学協会
前の記事 次の記事