低温工学
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
50/60Hz用超伝導極細多芯線における縦磁界損失の実験的評価
脈動縦磁界に対する交流損失
金高 仁吉屋 史生上田 秀樹岩熊 成卓船木 和夫竹尾 正勝山藤 馨三宅 清市熊野 智幸市原 政光
著者情報
ジャーナル フリー

1994 年 29 巻 7 号 p. 317-323

詳細
抄録
In multiply-twisted superconducting cables in a transverse external magnetic field, the strands of multifilamentary wires are exposed to a spatially periodic field component longitudinal to the strand axis. It is predicted theoretically in 50/60Hz region that the AC loss of the wires for the longitudinal component is not neglected or comparable with that for a pure transverse field in the multiply-twisted cables with cabling pitches of several cm and more. In the present paper, the AC loss in the spatially periodic longitudinal field was experimentally evaluated by means of measuring electromagnetically the AC loss of short multifilamentary wires in a 60Hz uniform longitudinal one. It results from a theoretical consideration that the above two types of losses are equivalent to each other within errors of 5%, where the sample length corresponds to a half of the wavelength of the field. The measured loss was quantitatively explained by the theoretical expression for spatially periodic longitudinal field above mentioned. These results suggest that the AC loss in the cables for AC use should be minimized under consideration of the longitudinal loss in addition to the usual transverse losses.
著者関連情報
© 社団法人低温工学協会
前の記事 次の記事
feedback
Top