低温工学
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
液体窒素の円管内流動圧力損失
遠藤 一夫敦賀 英男
著者情報
ジャーナル フリー

1973 年 8 巻 3 号 p. 105-108

詳細
抄録

The pressure drop of single phase liquid nitrogen flow in horizontal tube was measured. The tubes investigated were 0.305, 0.204 and 0.0723cm inner diameter and 200cm long and were immersed into the liquid nitrogen contained in a vacuum insulated vessel. Experiments were made with a Reynolds number range of 500-20, 000. The experimental data were presented in terms of the Fannings friction factor.
The results were in good agreement with theoretical line of newtonian liquid in the range of laminar flow and were approximately fit for the data obtained by newtonian liquid such as water in turbulent flow.

著者関連情報
© 社団法人低温工学協会
前の記事 次の記事
feedback
Top