2013 年 85 巻 11 号 p. 753-759
High purity (more than 4N) nitrogen gas can be used as a substitute gas for argon gas (5N) in molten aluminum treatment. The effects of nitrogen gas purity on molten aluminum treatment were clarified in this study.
AC8A (modified) alloy, four kinds of nitrogen gases (2N, 3N, 4N and 5N), and argon gas (5N) were prepared.
Equivalent removal of inclusion and fluidity were seen after molten aluminum treatment by each gas.