保健物理
Online ISSN : 1884-7560
Print ISSN : 0367-6110
ISSN-L : 0367-6110
Measurement of Dose Rates of a High-Level Gamma Irradiation Facility
P. S. Weng
著者情報
ジャーナル フリー

1967 年 2 巻 4 号 p. 160-165

詳細
抄録

LiF thermoluminescent dos meters were used to measure the dose rates in a high-level gamma irradiation facility which provides a wide range in dose level and various irradiation areas. A comparison of the discrepancies between observed data and calculated data based on a cylindrical source, point source, and line source is included.