燃料協会誌
Online ISSN : 2185-226X
Print ISSN : 0369-3775
ISSN-L : 0369-3775
ガスタービン用実規模触媒燃焼器によるメタン燃焼
福澤 久小沢 靖萬代 重實五良 哲雄
著者情報
ジャーナル フリー

1991 年 70 巻 9 号 p. 913-920

詳細
抄録
The methane combustion test at atmospheric pressure was carried out by using a full scale catalytic combustor with an improved Pd catalyst for 100MW gas tur-bine. The objective is to clarify the feasibility on application of high temperature catalytic combustion to gas turbines for the LNG combined cycle power plant system. The results can be summerized as follows:
1) The manufactured full scale catalytic combustor consists of a reverse annular pre-burner, an annular mixer and Pd catalyst. The dimensions of combustor is 450mm in dia-meter and 800mm in length.
2) Pd catalyst showed high activity in methane catalytic combustion and the combustion reaction proceeded enough at even lower temperatures corresponded to the compressed air temperature in gas turbine systems.
3) The catalytic combustor showed excellent performance in methane combustion at atmospheric pressure. The NOx emission was extremely low and the combustion efficiency was approximately 100% in wide range conditions. As a result, catalytic combustion is ex-pected to be applied to gas turbine combustors.
著者関連情報