Journal of the Japan Institute of Metals and Materials
Online ISSN : 1880-6880
Print ISSN : 0021-4876
ISSN-L : 0021-4876
Quantitative Auger Analysis for Fe Base Alloys Using Peak-to-Peak Value
Hiroyasu OmataHiroyuki Ogawa
Author information
JOURNAL FREE ACCESS

1978 Volume 42 Issue 12 Pages 1200-1205

Details
Abstract

A quantitative analysis for the iron-base alloys was made by Auger Electron Spectroscopy (AES). The specimens fractured in UHV (ultra high vacuum) were used. A linear relationship between relative peak height IXR for the element X(X=Cr, Ni and Mo) and the atomic percentage CX of the element X in Fe-X alloys was found. Relative sensitivity factor SXFe of the element X to iron was measured experimentally as the proportional constant for the relation between relative peak height IXR and the atomic percentage CX. The composition of alloying elements in Fe-Cr-Mo, Fe-Cr-Ni and Fe-Cr-Ni-Mo alloys was analysed using relative sensitivity factor SXFe. Reasult of AES analyses showed a good coincidence with the chemical analyses.

Content from these authors
© The Japan Institute of Metals