抄録

Objectives: The purpose of this study was to evaluate the efficacy of slightly acidic electrolyzed water (SAEW) against the contamination of the water line of dental units and the effects of SAEW on the water line.

Materials and Methods: The experimental material was a prototype dental unit equipped with a SAEW generator. SAEW is directly supplied to each device or part of this unit system. Experimental SAEW samples were collected from a high-speed handpiece (HS-1), an ultrasonic scaler, and a cup filler of the prototype dental unit. Control samples were taken before and after the prescribed flushing from another high-speed handpiece (HS-2) that is directly supplied with tap water in the same dental unit. The samples were analyzed for free chlorine and heterotrophic bacteria for 7 years to assess the efficacy and effects of SAEW. The substances eluted in SAEW were examined to investigate the effect of SAEW on the water line. A questionnaire survey was conducted on patients on whom dental uints supplied with SAEW were used.

Results: SAEW always showed a higher free chlorine concentration than tap water during the observation period of 7 years. In HS-2 supplied with tap water, the free chlorine concentration increased significantly owing to the prescribed flushing. SAEW always showed a significantly smaller number of heterotrophic bacteria than tap water. No abnormal levels values of water line components eluted into SAEW were observed. There were few negative comments from patients on whom dental units supplied with SAEW were used.

Conclusions: SAEW continuously used for 7 years was effective for contamination control in the water line of dental units.